FATS Series Thermal Mass Flowmeters
|
Application: Air, Nitrogen etc.
Accuracy: % 2 T.S.
Body: AISI316
Output: 4...20 mA
Assembly: Vertical&Horizontal
Supply: 24 V DC
Temperature: 0°C...80°C
Pressure: 16 bar max
Turndown Ratio: 20:1 women that cheat cheater what is infidelity
|
|
FSIA Series Thermal Mass Flowmeters
|
Rage: 0...250 Nm/s
Tmax: 177°C
Pmax: 70 bar
Connection: DN25...DN900 1/2” Thread
Accuracy: % 0,5
Output: Pulse, 4-20mA
Body: Stainless Steel, RS-485
Indicator: OLED Instant/Total coupons for cialis 2016 site free printable cialis coupons
|
|
FSIB Series Thermal Mass Flowmeters
|
Type: In-line or Insertion Integral
Measuring Size: 1/4"...30"
Sensor: 2xGrade Platinum RTDs
Power: 24VDC(100mA max)
Turndown Ratio: 100:1
Resolution: 1000:1
Accuracy: +- 0,5% F.S.
Temp.: -40..150°F
Repeatability: 0,2% women that cheat click what is infidelity
|
|
SAGE200 Series Thermal Mass Flowmeters
|
Application: Natural gas, air etc.
Sensor: AISI 316/Hastelloy C
Probe Size: 1/2" Insertion
Power: 24VDC, 115/230VAC
Process Temp.: -40...230°C
Process Pres.: 500 psig max
Accuracy: 0,5% of F.S.
Repeatability: 0,2% of reading
Turndown Ratio: 100:1 women that cheat click what is infidelity
|
|
FTMF Series Thermal Mass Flowmeters
|
Usage: Compressed-air, Nitrogen
Supply: 250mA at 24VDC
Operating Pres.: 16 bar max
Response Time: 1 second
Materials: Stainless Steel, Gold, Epoxy, Viton
Display: 4 digit LED
Output: 4-20 mA / 600 ohms & pulse how does abortion work go abortion clinics in san diego
|
|
TLF Series Thermal Mass Flowmeters
|
Gas: 0..10 cm3/min - 0..2000 lpm
Tmax: 50°C
Pmax: 35 bar
Connection: 1/4"...1” Thread
Accuracy: %1 Plastic or SS
Output: 4-20 mA or 0-5 VDC the morning after pill late abortion abortion clinics in colorado springs coupons for cialis 2016 open free printable cialis coupons
|
|
TSF Series Thermal Mass Flowmeters
|
Gas: 0...10 cm3/min - 0...100 lpm
Tmax: 50°C
Pmax: 35 bar, 1/2”
Accuracy: %1 Plastic or SS
Output: 4-20 mA or 0-5 V DC
Control: Built-in or 0-5 V DC why abortion should be illegal bartsha.cz abortions cost
|
|
TMF Series Thermal Mass Flowmeters
|
Gas: 0...200 slm
Tmax: 50°C
Pmax: 35 bar, 1/2” NPT
Accuracy: %1
Body: AISI 316
Display: Opt. LCD / Totalizer
Output: 4-20 mA or 0-5 V DC
Input: 24 VDC or 15 VDC
|
|
TMFC Series Thermal Mass Flowmeters
|
(with proportional valve)
Gas: 0...200 slm
Tmax: 50°C
Pmax: 35 bar, 1/2” NPT
Accuracy: %1
Body: AISI 316
Display: Opt. LCD / Totalizer
Output: 4-20 mA or 0-5 V DC
Control Signal: Integral or 0-5 VDC boyfriend cheated on me website online cialis trial coupon link coupon for cialis
|
|
|